  keysight vxa vector signal analysis x-series measurement application N9064A and w9064a technical overview C fft-based spectrum analysis C time-domain analysis tools for burst analysis C flexible modulation analysis C hardkey/softkey manual user interface or scpi remote user interface C built-in, context-sensitive help C transportable license between x-series signal analyzers
02 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview vxa vector signal analysis measurement application the vxa vector signal analysis measurement application transforms the x-series signal analyzers into vector signal analyzers by providing a wide range of measurements, demodulation types, and flters to perform comprehensive signal analysis, helping you thoroughly test your designs, ensure product quality, and optimize without compromise. the vxa vector signal analysis measurement application is just one in a common library of more than 25 measurement applications in the keysight x-series, an evolutionary approach to signal analysis that spans instrumentation, measurements, and software. the x-series analyzers, with upgradable cpu, memory, disk drives, and i/o ports, enable you to keep your test assets current and extend instrument longevity. proven algorithms, 100% code-compatibility, and a common ui across the x-series create a consistent measurement framework for signal analysis that ensures repeatable results and measurement integrity so you can leverage your test system software through all phases of product development. in addition to fxed, perpetual licenses for our x-series measurement applications, we also offer transportable licenses which can increase the value of your investment by allowing to you transport the application to multiple x-series analyzers. more about signal analysis the vxa measurement application is a general-purpose fft-based spectrum analysis application, with a wide selection of demodulation types and flters to perform fexible digital modulation analysis. C bring comprehensive vector signal analysis to the test rack C troubleshoot signals with powerful time domain capability C use analog demodulation to identify unintentional modulations C test when no commercial test standard is available C utilize fexible digital modulation analysis capability choosing between x-series applications and 89600 vsa software x-series measurement applications provide embedded format-specifc, one-button measurements for x-series analyzers. with fast measurement speed, scpi programmability, pass/fail testing and simplicity of operation, these applications are ideally suited for design verifcation and manufacturing. 89600 vsa software is a comprehensive set of tools for demodulation and vector signal analysis. these tools enable you to explore virtually every facet of a signal and optimize your most advanced designs. use the 89600 vsa software with a variety of keysight hardware platforms to pinpoint the answers to signal problems in r&d. www.keysight.com/ fnd/89600vsa
03 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview bringing comprehensive vector signal analysis to the test rack the vector signal analysis (option 1fp) is the foundation of all measurement options in the vxa measurement application and is a required option. each measurement is available simultaneously, in either one, two, three or four user-selected separate trace displays. you have full control of trace data format and scaling. C spectrum, instantaneous spectrum C time, instantaneous time, raw time C time gating C time averaging, including continuous repeat max hold, exponential max hold, rms (video), rms (video) exponential, time, time exponential C band power C power spectral density (psd) C power statistics (including gated): C complementary cumulative distribution function (ccdf) C cumulative distribution function (cdf) C probability distribution function (pdf) C auto correlation C occupied bandwidth (obw) C adjacent channel power (acp) C analog demodulation: am/fm/pm (includes spectrum, time, gated time, psd, power statistics) C frequency counter C signal tracking C marker coupling C ability to save traces vector signal analysis measurement details figure 1. basic vector signal analysis: the spectrum, time, and ccdf of the gated signal are shown, as well as the full time domain signal (trace 2, lower left).
04 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview figure 2. analog demodulation: pm demodulation showing phase stability of the burst at turn-on; by coupling markers to an expanded time domain trace, we can see that data is sent prior to the phase settling out to a stable value after the burst turn-on occurs. figure 3. 2x2 grid display showing multiple measurements, markers, and marker table for at-a-glance signal analysis. vector signal analysis measurement details (continued)
05 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview view detailed frequency behavior the vxa measurement application gives you a complete set of tools to maximize the resolution of your spectrum display and the accuracy of the data displayed: C up to 409601 frequency points across whatever frequency span you select provides unprecedented frequency resolution to locate the most diffcult problem; rbws of less than 1 millihertz are available C automatic selection of highest frequency resolution for a given measurement C four different fft window functions to choose from to meet specifc measurement needsgaussian flter for high dynamic range measurements, or fat top flter for highest amplitude accuracy measurements amplitude accuracy measurements C use the x-axis scaling feature for a better view of the area of interest on the signal; save this display or paste the measurement result into a report to the design team figure 4. the fft window flter is applied to each frequency bin, similar to the flter that a spectrum analyzer uses as it sweeps across the frequency span of the measurement; however, with vxa, the flters are applied simultaneously to all frequencies and can be changed. figure 5. high-resolution frequency and time domain traces; trace 3 shows the same time with the x-axis expanded to improve resolution of burst turn-on. enhance your time to insight for baseband signal quality the option 1fp enables the pxa or mxa signal analyzers (with option bba installed) to expand the baseband analysis capability for troubleshooting and design verifcation of rf devices.
06 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview add powerful analysis options the fexible digital modulation analysis option, option 2fp, adds the capability to visualize system performance rapidly and intuitively. teamed with an keysight x-series signal analyzer, you can increase the speed of your measurement tasks with the fexibility this option offers: C customize modulation analysis formats including psk, qam (16 to 1024qam), msk, edge, fsk, vsb, dvbqam, apsk, soqpsk C a complete set of more than 30 modulation quality measurements, including overall evm, peak evm, evm vs. symbol time, evm spectrum, time, spectrum, constellation diagram, vector diagram, iq parameters, requency and clock error, channel/impulse response with eq flter, zero crossing error, and symbol clock error C convenient measurement presets to cover popular communication formats, such as cdma, gsm/edge, bluetooth ? , zigbee, tetra, apco25, and wi-sun (mr-fsk phy) testing when no commercial test standard is available testing proprietary and custom signals is a challenge. turnkey test software for those signals is seldom available off-the-shelf, so you have to design and implement the tests yourself. the fexible digital modulation analysis option will help you with that task. it covers the various demands of do it yourself testing for single carrier, single modulation signals with a deep set of fexible modulation analysis tools that you can tweak to meet your needs. in addition, these fexible tools are scpi programmable. flexible digital modulation analysis figure 6. qpsk modulation analysis in default quad view: trace 1 (upper left), iq constellation; trace 2 (lower left), spectrum; trace 3 (upper right), error vector magnitude versus time (symbol) trace; trace 4 (lower right), symbols/error table.
07 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview standard presets (for single carrier) cellular cdma (base, mobile), cdpd, edge, gsm, nadc, pdc, phs (php), w-cdma wireless networking bluetooth (basic rate), hiperlan/1 (hbr, lbr), wlan (802.11b), zigbee (802.15.4, 868/915/2450 mhz), wi-sun (802.15.4g, mr-fsk phy) digital video dtv (8, 16), dvb (16, 32, 64, 128, 256), dvb (16apsk, 32apsk) other apco 25, apco 25 p2 (hcpm), apco 25 p2 (hdqpsk), dect, tetra, vdl mode 3, mil-std 188-181c, soqpsk-tg modulation formats fsk 2, 4, 8, 16 level (including gfsk) msk (including gmsk) bpsk, qpsk, oqpsk, dqpsk, d8psk, /4dqpsk, 8psk, 3/8 8psk (edge), /8 d8psk, soqpsk qam (absolute encoding) 16, 32, 64, 128, 256, 512, 1024 qam (differential encoding per dvb standard) 16, 32, 64, 128, 256 apsk 16, 16 w/dvb, 32, 32 w/dvb vsb 8, 16 filter types raised cosine, square-root raised cosine, is-95 compatible, gaussian, edge, 1rec, 3rc, soqpsk-tg, low pass, rectangular, half-sine, none alpha/bt continuously adjustable from 0.05 to 10 user-defned flters adaptive equalizer decision directed, lms, feed-forward, equalization with adjustable convergence rate; removes the effects of linear distortion (i.e. non-fat frequency response, multipath, etc.) from modulation quality measurements symbol rate rate = frequency span / (1+ ); maximum symbol rate limited only by the measurement span advanced analysis setup burst search pulse search sync search (with user-selected synchronization word) adjustable search length and offset timing measurements/displays eye diagram trellis diagram polar diagram constellation and vector (shows trajectory between symbol times) diagram i and q versus time error vector magnitude evm versus symbol time evm versus frequency magnitude and phase error frequency error (carrier offset frequency) iq origin offset quadrature error gain imbalance amplitude droop (psk and msk formats) snr (8/16vsb and qam formats) symbols table (demodulated bits) error table with tabular evm and iq errors equalizer channel frequency response equalizer imipulse response symbol clock error zero crossing error key features of digital modulation analysis
08 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview key specifcations defnitions C specifcations describe the performance of parameters covered by the product warranty. C 95th percentile values indicate the breadth of the population (2 ) of performance tolerances expected to be met in 95% of cases with a 95% confdence. these values are not covered by the product warranty. C typical values are designated with the abbreviation "typ." these are performance beyond specifcation that 80% of the units exhibit with a 95% confdence. these values are not covered by the product warranty. C nominal values are designated with the abbreviation "nom." these values indicate expected performance, or describe product performance that is useful in the application of the product, but is not covered by the product warranty. C pxa specifcations apply to analyzers with frequency options of 526 and lower. for analyzers with higher frequency options, specifcations are not warranted but performance will nominally be close to that shown in this section. note: data subject to change option 1fp vector signal analysis option description pxa mxa exa cxa maximum frequency 50 ghz 26.5 ghz 44 ghz 26.5 ghz external mixing support with option exm yes yes yes n/a center frequency tunning resolution + 1 mhz 1 mhz 1 mhz frequency span 10 mhz (standard); 25 mhz (option b25) 40 mhz (option b40) 85 mhz (option b85) 160 mhz (option b1x) 25 mhz (standard) 40 mhz (option b40) 85 mhz (option b85) 125 mhz (option b1a) 160 mhz (option b1x) 25 mhz (standard) 40 mhz (option b40) 10 mhz (standard) 25 mhz (option b25) frequency point per span calibrated points: 51 ~ 409, 601; displayed points: 51 ~ 524, 288 absolute amplitude accuracy (freq < 3.6 ghz) 0.19 db, 95% frqoghqfhdffxudf 0.23 db, 95% frqoghqfhdffxudf 0.27 db, 95% frqoghqfhdffxudf 0.50 db, (freq < 3 ghz) 95% frqoghqfhdffxudf third-order intermodulation distortion, two C20 dbfs tones, 400 mhz to 13.6 ghz, (7.5 ghz for cxa) tone separation > 15 khz C90 dbc (nom) C90 dbc (nom) C84 dbc (nom) C66 dbc (nom) resolution bandwidth rbws range from less than 1 hz to greater than 2.8 mhz (standard); greater than 7 mhz (with option b25) 5%:oowhuvkdshv flat top, gaussian top, hanning, uniform analog demodulation types am, fm, pm
09 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview for a complete list of specifcations refer to the appropriate specifcations guide. pxa: www.keysight.com/fnd/pxa_specifcations mxa: www.keysight.com/fnd/mxa_specifcations exa: www.keysight.com/fnd/exa_specifcations cxa: www.keysight.com/fnd/cxa_specifcations x-series signal analyzers accuracy pxa mxa exa cxa bbiq 1 conditions modulation formats include bpsk, d8psk, dqpsk, qpsk, (16/32/64/128/256/512/1024) qam, (16/32/64/128/256)dvbqam, /4-dqpsk, 8-psk. evm normalization reference set to constellation maximum. transmit flter is root raised cosine with alpha=0.35. center frequency 1 ghz. signal amplitude of 16 dbm, analyzer range set to 10 dbm. result length set to at least 150 symbols, or 3 {number of ideal state locations}. rms style averaging with a count of 10. phase noise optimization adjusted based on symbol rate of measurement. available span dependent on analyzer hardware bandwidth options. residual errors symbol rate/span residual evm 1 msps/5 mhz 0.5% rms 0.7% rms 0.7% rms 0.7% rms 0.5% rms 10 msps/25 mhz 0.5% rms 0.7% rms 0.7% rms 0.9% rms 0.5% rms 25 msps/40 mhz 0.7% rms 1.1% rms 1.1% rms 0.6% rms 100 msps/160 mhz 1.0% rms 1.3% rms magnitude error 1 msps/5 mhz 0.4% rms 0.5% rms 0.5% rms 0.5% rms 0.5% rms 10 msps/25 mhz 0.5% rms 0.5% rms 0.5% rms 0.6% rms 0.5% rms 25 msps/40 mhz 0.6% rms 0.8% rms 0.8% rms 0.6% rms 100 msps/160 mhz 0.9% rms 1.0% rms phase error 1 msps/5 mhz 0.5 rms 0.6 rms 0.6 rms 0.7 rms 0.6 rms 10 msps/25 mhz 0.6 rms 0.6 rms 0.6 rms 0.8 rms 0.6 rms 25 msps/40 mhz 0.6 rms 1.1 rms 1.1 rms 0.6 rms 100 msps/160 mhz 1.0 rms 1.3 rms frequency error added to frequency accuracy if applicable symbol rate / 500,000 i/q origin offset 1 60 db accuracy pxa mxa exa cxa bbiq 1 conditions modulation formats include msk and msk2. transmit flter is gaussian with bt=0.3. center frequency 1 ghz. signal amplitude of -16 dbm. analyzer range set to 10 dbm. result length set to 150 symbols. rms style averaging with a count of 10. available span dependent on analyzer hardware bandwidth options. residual errors symbol rate/span residual evm 10 msps/25 mhz 0.5% rms 0.9% rms 0.9% rms 1.0% rms 0.8% rms 80 msps/160 mhz 1.4% rms 1.8% rms phase error 10 msps/25 mhz 0.4 rms 0.5 rms 0.5 rms 0.5 rms 0.5 rms 80 msps/160 mhz 1.3 rms 1.3 rms 1. i+jq measurements performed using signal amplitude and analyzer range near 0 dbm, with a 0 hz center frequency. i/q origin offset metric does not include impact of analyzer dc offsets. key specifcations (continued)
10 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview ordering information software licensing and confguration choose from two license types: C fixed, perpetual license: this allows you to run the application in the x-series analyzer in which it is initially installed. C transportable, perpetual license: this allows you to run the application in the x-series analyzer in which it is initially installed, plus it may be transferred from one x-series analyzer to another. the table below contains information on our fxed, perpetual licenses. for more information, please visit the product web pages. N9064A & w9064a vxa vector signal analysis measurement application description model-option additional information pxa, mxa, exa cxa vector signal analysis N9064A-1fp w906 4a-1fp flexible digital modulation N9064A-2fp w9064a-2fp requires 1fp web product page: C www.keysight.com/fnd/N9064A C www.keysight.com/fnd/w9064a x-series measurement applications: C www.keysight.com/fnd/x-series_apps x-series signal analyzers: C www.keysight.com/fnd/x-series related literature description publication number N9064A & w9064a vector signal analysis, self-guided demonstration 5990-6159en N9064A & w9064a vector signal analysis, measurement guide n9064-90004 user's and programmer's reference guide is available in the library section of the N9064A and w9064a product pages. try before you buy free 30-day trials of x-series measurement applications provide unrestricted use of each applications features and functionality on your x-series analyzer. redeem a trial license on-line today: www.keysight.com/fnd/x- series_trial options can be added after your initial purchase. all of our x-series application options are license-key upgradeable. x-series measurement application updates to updat e a previously purchased N9064A/w9064a measurement application to include the latest feature updates, you can purchase the N9064A-meu or w9064a-meu minor enhancement update. for more information, visit: www.keysight.com/fnd/ N9064A-meu for pxa, mxa, exa www.keysight.com/fnd/ w9064a-meu for cxa
mykeysight www.keysight.com/find/mykeysight a personalized view into the information most relevant to you. three-year warranty www.keysight.com/find/threeyearwarranty keysights commitment to superior product quality and lower total cost of ownership. the only test and measurement company with three-year warranty standard on all instruments, worldwide. keysight assurance plans www.keysight.com/find/assuranceplans up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality keysight technologies, inc. dekra certified iso 9001:2008 quality management system keysight channel partners www.keysight.com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience. bluetooth and the bluetooth logos are trademarks owned by bluetooth sig, inc., u.s.a. and licensed to keysight technologies, inc. for more information on keysight technologies products, applications or services, please contact your local keysight office. the complete list is available at: www.keysight.com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacifc australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 112 929 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 0800 000154 sweden 0200 882255 switzerland 0800 805353 opt. 1 (de) opt. 2 (fr) opt. 3 (it) united kingdom 0800 0260637 for other unlisted countries: www.keysight.com/find/contactus (bp-07-10-14) 11 | keysight | vxa vector signal analysis x-series measurement application N9064A and w9064ab - technical overview this information is subject to change without notice. ? keysight technologies, 2014 published in usa, september 24, 2014 5990-5918en www.keysight.com


▲Up To Search▲   

 
Price & Availability of N9064A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X